Skip to main content

MultiPlus-II 120V

7. Technical specifications

In this section:

MultiPlus-II 120V

12/3000/120-50

12/4k/160-50

24/3000/70-50

48/3000/35-50

PowerControl & PowerAssist

Yes

Transfer switch

50A

Maximum AC input current

50A

INVERTER

DC Input voltage range

9.5 - 17V

9.5 - 17V

19 - 33V

38 - 66V

Output in inverter mode

Output voltage: 120VAC ± 2%

Frequency: 60Hz ± 0.1%

Continuous output power at 25°C (2)

3000VA

3000VA

3000VA

Continuous output power at 25°C

2400W

3.4kW

2400W

2400W

Continuous output power at 40°C

2200W

3.1kW

2200W

2200W

Continuous output power at 65°C

1700W

2.4kW

1700W

1700W

Time limited power 1 (cold start)

4.0kW/1h

Time limited power 2 (cold start)

4.5kW/30min

Peak power

5500W

6kW/2s

5500W

5500W

Maximum efficiency

93%

93%

94%

95%

Zero load power

13W

18W

13W

11W

Zero load power in AES mode

9W

11W

9W

7W

Zero load power in Search mode

3W

4W

3W

2W

CHARGER

AC Input

Single phase: 90-140VAC 55 - 65Hz

Charge voltage 'absorption'

14.4V

14.4V

28.8V

57.6V

Charge voltage 'float'

13.8V

13.8V

27.6V

55.2V

Storage mode

13.2V

13.2V

26.4V

52.8V

Maximum battery charge current (3)

120A

160A

70A

35A

Battery temperature sensor

Yes

Optional. Order number: ASS000001000

GENERAL

Auxiliary output (4)

32A

External AC current sensor (optional)

100A

Programmable relay (5)

Yes

Protection (1)

a - g

VE.Bus communication port

For parallel, split phase and three phase operation, remote monitoring and system integration

General purpose com. port (6)

Yes, 2x

Remote on-off

Yes

Ambient temperature range

-40 to +65°C (-40 - 150°F) fan assisted cooling

Maximum humidity (non-condensing)

95%

ENCLOSURE

Material & Colour

Steel, blue RAL 5012

Protection category

IP21

Battery-connection

2x2 M8 bolts

2x2 M8 bolts

2 M8 bolts

2 M8 bolts

120 VAC connection

Screw terminals 13mm² (6 AWG)

Weight

19 kg (42 lb)

22 kg (49 lb)

19 kg (42 lb)

19 kg (42 lb)

Dimensions hxwxd

578 x 277 x 148 mm

22.7 x 10.9 x 5.8 inch

631 x 277 x 164 mm

24.8 x 10.9 x 6.5 inch

536 x 277 x 147 mm

21.1 x 10.9 x 5.8 inch

572 x 277 x 147 mm (7)

22.5 x 10.9 x 5.8 inch (7)

STANDARDS

Listing

UL 458

UL 458

UL 458

UL1741

Safety

EN-IEC 60335-1, EN-IEC 60335-2-29, CSA 22.2 107.1-16

Emission, Immunity

EN 55014-1, EN 55014-2

EN-IEC 61000-3-2, EN-IEC 61000-3-3

IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

  1. Protection key:

    1. output short circuit

    2. overload

    3. battery voltage too high

    4. battery voltage too low

    5. temperature too high

    6. 120VAC on inverter output

    7. input voltage ripple too high

  1. Non-linear load, crest factor 3:1

  2. Up to 75°F / 25°C ambient

  3. Switches off when no external AC source available

  4. Programmable relay, which can be set for general alarm, DC under voltage or genset start/stop function. AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC

  5. Use, for example, to communicate with a Lithium-Ion battery BMS

  6. Dimensions of the not UL1741 certified model:     536 x 277 x 147 mm / 21.1 x 10.9 x 5.8 inch

MultiPlus-II 120V

24/5000/120-95

48/5000/70-95

PowerControl & PowerAssist

Yes

Transfer switch

95A

Maximum AC input current

95A

INVERTER

DC Input voltage range

19 - 33V

48V

Output in inverter mode

Output voltage: 120VAC ± 2%

Frequency: 60Hz ± 0,1%

Continuous output power at 25°C (2)

5000VA

Continuous output power at 25°C

4000VA

Continuous output power at 40°C

3700VA

Continuous output power at 65°C

3000VA

Peak power

9000VA

Maximum efficiency

95%

96%

Zero load power

24W

19W

Zero load power in AES mode

10W

10W

Zero load power in Search mode

3W

3W

CHARGER

AC Input

Single phase: 90-140VAC 45-65Hz

Charge voltage 'absorption'

28.8V

57.6V

Charge voltage 'float'

27.6V

55.2V

Storage mode

26.4V

52.8V

Maximum battery charge current (3)

95A

70A

Battery temperature sensor

Yes

Optional. Order number: ASS000001000

GENERAL

Auxiliary output (4)

43A

48A

External AC current sensor (optional)

100A

Programmable relay (5)

Yes

Protection (1)

a – g

VE.Bus communication port

For parallel, split phase and three phase operation, remote monitoring and system integration

General purpose com. port (6)

Yes, 2x

Remote on-off

Yes

Pollution Degree (PD) & Overvoltage Category (OVC)

PD: 2 & OVC III

Ambient temperature range

-40 to +60°C (-40 - 140°F) fan assisted cooling

Humidity (non-condensing)

max 95%

ENCLOSURE

Material & Colour

Steel, blue RAL 5012

Protection category

IP21

Battery-connection

2x M8 bolts

120 VAC connection

35mm2 (2 AWG)

Weight

29 kg (64 lb)

32 kg (70 lb)

Dimensions hxwxd

627 x 350 x 150 mm

4.7x13.8x5.9 inch

676x329x164 mm

26.6 x 13.0 x 6.5 inch

STANDARDS

Listings

-

UL1741

Safety

EN-IEC 60335-1, EN-IEC 60335-2-29, CSA 22.2 107.1-16

Emission, Immunity

EN 55014-1, EN 55014-2

EN-IEC 61000-3-2, EN-IEC 61000-3-3

IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

  1. Protection key:

    1. output short circuit

    2. overload

    3. battery voltage too high

    4. battery voltage too low

    5. temperature too high

    6. 120 VAC on inverter output

    7. input voltage ripple too high

  1. Non-linear load, crest factor 3:1

  2. Up to 75°F / 25°C ambient

  3. Switches off when no external Ac source available

  4. Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC

  5. Use, for example, to communicate with a Lithium-Ion battery BMS

  6. Dimensions of the not UL1741 certified model:     536 x 277 x 147 mm / 21.1 x 10.9 x 5.8 inch

MultiPlus-II 120V 50/60Hz

12/4k/160-50

PowerControl & PowerAssist

Yes

Transfer switch

50A

Maximum AC input current

50A

INVERTER

DC Input voltage range

9.5 - 17V

Output in inverter mode

Output voltage: 120VAC ± 2%

Frequency: 60Hz ± 0.1% (1)

Continuous output power at 25°C

3.4kW

Continuous output power at 40°C

3.1kW

Continuous output power at 65°C

2.4kW

Time limited power 1 (cold start)

4.0kW/2h

Time limited power 2 (cold start)

4.5kW/30min

Peak power

6kW/2s

Maximum efficiency

93%

Zero load power

18W

Zero load power in AES mode

11W

Zero load power in Search mode

4W

CHARGER

AC Input

Single phase: 90-140VAC 45 - 65Hz

Charge voltage 'absorption'

14.4V

Charge voltage 'float'

13.8V

Storage mode

13.2V

Maximum battery charge current (3)

160A

Battery temperature sensor

Yes

GENERAL

Auxiliary output (4)

32A

External AC current sensor (optional)

100A

Programmable relay (5)

Yes

Protection (1)

a - g

VE.Bus communication port

For parallel, split phase and three phase operation, remote monitoring and system integration

General purpose com. port (6)

Yes, 2x

Remote on-off

Yes

Ambient temperature range

-40 to +65°C (-40 - 150°F) fan assisted cooling

Maximum humidity (non-condensing)

max 95%

ENCLOSURE

Material & Colour

Steel, blue RAL 5012

Protection category

IP21

Battery-connection

2x2 M8 bolts

120 VAC connection

Screw terminals 13mm² (6 AWG)

Weight

22 kg (49 lb)

Dimensions hxwxd

631 x 277 x 164 mm

24.8 x 10.9 x 6.5 inch

STANDARDS

Listing

UL 458

Safety

EN-IEC 60335-1, EN-IEC 60335-2-29, CSA 22.2 107.1-16

Emission, Immunity

EN 55014-1, EN 55014-2

EN-IEC 61000-3-2, EN-IEC 61000-3-3

IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

  1. Can be adjusted to 50Hz

  2. Protection key:

    1. output short circuit

    2. overload

    3. battery voltage too high

    4. battery voltage too low

    5. temperature too high

    6. 120VAC on inverter output

    7. input voltage ripple too high

  1. Non-linear load, crest factor 3:1

  2. Up to 75°F / 25°C ambient

  3. Programmable relay, which can be set for general alarm, DC under voltage or genset start/stop function. AC rating: 120V / 4A, DC rating: 4A up to 35VDC and 1A up to 60VDC

  4. Use, for example, to communicate with a Lithium-Ion battery BMS